Bk-precision 1696-1698 - Manual User Manual

Browse online or download User Manual for Power suppliers Bk-precision 1696-1698 - Manual. B&K Precision 1696-1698 - Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTRUCTION
MANUAL
MANUAL DE INSTRUCCIONES
Model 1696/1697/1698
Modelo 1696 / 1697 / 1698
LABORATORY GRADE
SWITCHING MODE
PROGRAMMABLE DC
POWER SUPPLIES with
PC INTERFACE
Page view 0
1 2 3 4 5 6 ... 38 39

Summary of Contents

Page 1 - Model 1696/1697/1698

INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES Model 1696/1697/1698 Modelo 1696 / 1697 / 1698 LABORATORY GRADE SWITCHING MO

Page 2 - TABLE OF CONTENTS

10 Upper Voltage Limit Setting This feature limits the upper level setting of output voltage to prevent inadvertent setting of high voltage, which m

Page 3

11 OPERATING INSTRUCTIONS Showing output terminals in ON/OFF state. Showing keypad & Jog dial are in Locked (de-activated) or Unlock (activat

Page 4

12 STANDARD OPERATION SYMBOLS V- const Constant Voltage mode showing set voltage. V- set This only appears voltage level is ready for setting

Page 5 - 3. INTRODUCTION

13 6.2 Manual Operation Mode In the Manual Operation Mode, once the voltage and current levels have been set, the unit wi11 keep these settings e

Page 6

14 and returns to its old settings Note : If during any of the above keypad operations, you fall to input a setting within 10 seconds, the unit will

Page 7 - 4. CONTROLS AND INDICATORS

15 go to the next Preset. Whenever you want to determine Preset Programming you can press the CLEAR key to return to normal operation mode. Selecti

Page 8

16 9. A subprogram is confirmed to retain the new settings only when procedure 7 is completed. 10. You can always input zero time period as a termi

Page 9 - 6. OPERATING INSTRUCTIONS

17 Note: Beware that the life span of the power supply is limited by the life of the relay, which is l 00x 10,000 operation as stated by the relay

Page 10

18 2. Symbols Running in a Timed Program Cycle Unit is ready for the recheck of all subprogram settings.

Page 11

19 8. MAINTENANCE 8.1 RECALIBRATION Introduction This in-case recalibration is to reduce the difference between the Set values and the displ

Page 12

2 TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS & PRECAUTIONS FOR USE ... 3

Page 13

20 8.2 TROUBLE SHOOTING 1. Keypad and Dial do not work. Check key lock symbol for lock state, unlock unit by pressing SHIFT then Lock/Unlock k

Page 14 - Preset Programming

21 9. PC INTERFACE CONTROL USER MANUAL 9.1 Introduction We integrate the micro-controller technology and our proprietary software with switching

Page 15 - Selecting Presets

22 Installation of software 1. Run Setup.EXE with installation disk that comes with the unit. 2. Follow the instructions in the setup program. Duri

Page 16

23 If it shows No Connection, check the following: A. Go back to setup and check to see if the correct COM port has been assigned. B. Check the pow

Page 17

24 C Min Minimum current level. C Max. Maximum current level. V Min. Minimum power level in watt. W Max. Maximum power level in watt. 3. Log

Page 18

25 8. XXX Delete Clicking on this icon will delete the current or retrieve log on display at (3). 9. Print Log in xls format. P.22 THE DATA LOG W

Page 19 - 8. MAINTENANCE

26 THE TIME FRAME CONCEPT OF DATA LOG The data logging function starts when the software begins to run. When T Min is set to zero seconds, it mea

Page 20

27 GENERAL INFORMATION Please refer to (Fig. 3) for the following description. 10. Power Supply Description: You may click on and assign an i

Page 21

28 16. OUTPUT Left click on icon will switch on or off the output. Internal Timed Program The PC interface remote mode really eliminates the tedi

Page 22

29 4. Data exceeding the rated voltage and current will not be accepted. 5. Voltage exceeding set UVL (upper output voltage limit) will not be acce

Page 23

3 1. IMPORTANT SAFETY INSTRUCTIONS 1. Do not use this apparatus near water. 2. Clean only with dry cloth. 3. Do not block any ventilation o

Page 24

30 3. On your power supplies, press [SHIFT] key, then quickly press [RS-232/485] key and select RS-485. 4. A 3-digit number will be displayed.

Page 25 - 8. XXX Delete

31 9.4.2 Configuration of Multi Windows Analysis 1. In the tool bar, click on Supply Connect, then click on Multi in the drop menu. 2. A mult

Page 26

32 4. Click on AutoScan Connect, the window will show the connected power supply indicated with “Y”. 5. Click on the box along

Page 27 - 0------0

33 8. Remarks: 1. Multi Alleyway Display one click and it will display the Data Log and output data of all the power

Page 28

34 You can click on the data log to select the power supply, the data log will highlight in blue and the address bar in the lef

Page 29

35 6. Log Thumbnails Size Set Up - one click allows user to adjust the window size of the Data Log Window in Multi Alleyway Display. Use the sliders

Page 30 - (FIG 4)

36 10. Delete Log It will delete log data in PC 11. Export to a file log of xls type Click on this icon to export t

Page 31

37 Service Information Warranty Service: Please return the product in the original packaging with proof of purchase to the address below. Clearl

Page 32 - (FIG. 7)

38 Limited One-Year Warranty B&K Precision Corp. warrants to the original purchaser that its products and the component parts thereof will

Page 33

39 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com © 2006 B&K Precision Corp. Printed in

Page 34 - (FIG. 9)

4 2. Technical Specifications of models 1696, 1697, 1698 Specifications 1696 1697 1698 Output Voltage 1-20VDC 10-5A -40VDC 1-60VDC Output Current

Page 35

5 Weight 6.6lbs. (3Kg) Accessory PC Windows TM software, RS-232 cable and Operation manual 3. INTRODUCTION This series of laboratory grade, switchi

Page 36

6 4. CONTROLS AND INDICATORS 1. JOG DIAL 2. UP & DOWN KEY 3. DUAL FUNCTION CONTROL KEYS 4. BLACK COLOR NEGATIVE POLAR

Page 37 - Service Information

7 4. CONTROLS AND INDICATORS 7. POWER SWITCH 8. AC 100 - 240VAC POWER SOCKET WITH INPUT POWER FUSE 9. RS-232 PORT 10. RS-

Page 38 - Limited One-Year Warranty

8 5. GENERAL OPERATION PRINCIPLE There are four operation methods for this unit: • Manual Operation • Presets • Timed Program • PC Interface

Page 39

9 Program 1 to 9 is for nine sets of Presets of voltage and current. The program 0 is reserved for the 20 timed subprograms; each is capable of stori