BK Precision 19*00 Instruction Manual

Browse online or download Instruction Manual for Power supply units BK Precision 19*00. BK Precision 19*00 Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTRUCTION
MANUAL
MANUAL DE INSTRUCCIONES
Model 1696/1697/1698
Modelo 1696 / 1697 / 1698
LABORATORY GRADE
SWITCHING MODE
PROGRAMMABLE DC
POWER SUPPLIES with
PC INTERFACE
Page view 0
1 2 3 4 5 6 ... 38 39

Summary of Contents

Page 1 - Model 1696/1697/1698

INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES Model 1696/1697/1698 Modelo 1696 / 1697 / 1698 LABORATORY GRADE SWITCHING MO

Page 2 - TABLE OF CONTENTS

10 OPERATING INSTRUCTIONS Precaution Reset back to the maximum rated voltage of the unit is recommended to avoid false fault report of the unit 1. P

Page 3

11 OPERATING INSTRUCTIONS Showing output terminals in ON/OFF state. Showing keypad & Jog dial are in Locked (de-activated) or Unlock (activated)

Page 4

12 STANDARD OPERATION SYMBOLS V- const Constant Voltage mode showing set voltage. V- set This only appears voltage level is ready for setting.

Page 5 - 3. INTRODUCTION

13 6.2 Manual Operation Mode In the Manual Operation Mode, once the voltage and current levels have been set, the unit wi11 keep these settings even

Page 6

14 7. USING THE PRESET FEATURES PRESET PROGRAM SYMBOLS Program Unit is ready for inputting of a Preset Program Number (19). Recall Unit is rea

Page 7 - 4. CONTROLS AND INDICATORS

15 Selecting Presets 1. Press the RECALL key The display will show Recall_ 2. Press the number key (1-9). The display will show the chosen Preset N

Page 8

16 Note: A. Once the subprograms are filled, the unit will return to manual operation mode. B. Any subprogram with zero time period will become th

Page 9 - 6. OPERATING INSTRUCTIONS

17 TIMED PROGRAM SYMBOLS 1. Inputting Subprograms

Page 10

18 2. Symbols Running in a Timed Program Cycle Unit is ready for the recheck of all subprogram settings.

Page 11

19 8. MAINTENANCE 8.1 RECALIBRATION Introduction This in-case recalibration is to reduce the difference between the Set values and the displayed

Page 12

2 TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS & PRECAUTIONS FOR USE ... 3

Page 13 - 6.2 Manual Operation Mode

20 8.2 TROUBLE SHOOTING 1. Keypad and Dial do not work. Check key lock symbol for lock state, unlock unit by pressing SHIFT then Lock/Unlock key,

Page 14 - Preset Programming

21 9. PC INTERFACE CONTROL USER MANUAL 9.1 Introduction We integrate the micro-controller technology and our proprietary software with switching mod

Page 15 - Selecting Presets

22 9.3 Operation Instruction for RS-232 Interface 1. Ensure that the PC is off; connect RS-232 to serial COM port of your PC and the power supply.

Page 16

23 1. Setting Once you bring up the software you can your desired sample time from 1 second up from the drop menu. Data log Sampling Time You c

Page 17

24 3. Log Name Click cursor on "Untitle", type in a name for your log. Note how the ###(5) icon changes to solid color. 4. Log Descri

Page 18

25 THE DATA LOG WINDOW DISPLAY

Page 19 - 8. MAINTENANCE

26 THE TIME FRAME CONCEPT OF DATA LOG The data logging function starts when the software begins to run. When T Min is set to zero seconds, it means

Page 20

27 GENERAL INFORMATION Please refer to (Fig. 3) for the following description. 10. Power Supply Description: You may click on and assign an ident

Page 21

28 Internal Timed Program The PC interface remote mode really eliminates the tedious process in keying in groups of entries on the power supply. Bec

Page 22

29 Internal Preset Memory The operation principle is the same as Internal Timed Program To activate the selected preset, click on the box of the [Se

Page 23

3 1. IMPORTANT SAFETY INSTRUCTIONS 1. Do not use this apparatus near water. 2. Clean only with dry cloth. 3. Do not block any ventilation o

Page 24

30 3. On your power supplies, press [SHIFT] key, then quickly press [RS-232/485] key and select RS-485. 4. A 3-digit number will be displayed

Page 25

31 9.4.2 Configuration of Multi Windows Analysis 1. In the tool bar, click on Supply Connect, then click on Multi in the drop menu. 2. A multi-wi

Page 26

32 4. Click on AutoScan Connect, the window will show the connected power supply indicated with “Y”. 5. Click on the box along the

Page 27 - 0------0

33 8. Remarks: 1. Multi Alleyway Display one click and it will display the Data Log and output data of all the power

Page 28

34 You can click on the data log to select the power supply, the data log will highlight in blue and the address bar in the left bot

Page 29 - (FIG 4)

35 7. Save Log: a. Click on it and save log window (Fig. 13) will appear. b. Click on the box along the Save column to choose the desired

Page 30

36 8. Delete Log It will delete log data in PC 9. Export to a file log of xls type Click on this icon to export the

Page 31 - (FIG. 6)

37 Service Information Warranty Service: Please return the product in the original packaging with proof of purchase to the address below. Clearly

Page 32 - (FIG. 7)

38 Limited One-Year Warranty B&K Precision Corp. warrants to the original purchaser that its products and the component parts thereof will b

Page 33

39 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com © 2006 B&K Precision Corp. v 082014

Page 34 - (FIG. 9)

4 2. Technical Specifications of models 1696, 1697, 1698 Specifications 1696 1697 1698 Output Voltage 1-20VDC 10-5A -40VDC 1-60VDC Output Current

Page 35

5 Weight 6.6lbs. (3Kg) Accessory PC Windows TM software, RS-232 cable and Operation manual 3. INTRODUCTION This series of laboratory grade, switchi

Page 36

6 4. CONTROLS AND INDICATORS 1. JOG DIAL 2. UP & DOWN KEY 3. DUAL FUNCTION CONTROL KEYS 4. BLACK COLOR NEGATIVE POLAR

Page 37 - Service Information

7 4. CONTROLS AND INDICATORS 7. POWER SWITCH 8. AC 100 - 240VAC POWER SOCKET WITH INPUT POWER FUSE (T4A, 250V) 9. RS-232 P

Page 38 - Limited One-Year Warranty

8 5. GENERAL OPERATION PRINCIPLE There are four operation methods for this unit:  Manual Operation  Presets  Timed Program  PC Interface Mo

Page 39

9 6. OPERATING INSTRUCTIONS 6.1 Setting of Operation Modes Output On/Off Mode 1. Press SHIFT key. The display will show Sh:Ft. 2. Press (O/P On

Comments to this Manuals

No comments