Bk-precision 1737 - Manual User Manual

Browse online or download User Manual for Power suppliers Bk-precision 1737 - Manual. B&K Precision 1737 - Manual User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Dual Range DC Power Supply

Model 1737 Dual Range DC Power Supply INSTRUCTION MANUAL

Page 2

8 4 Operating Instructions Safety Precautions Use only a polarized 3-wire AC outlet. This assures that the power supply chassis, case, and ground te

Page 3 - 1 Safety Summary

9 4.1 Instrument Hook-Up 1. Turn off the power supply and the equipment to be powered during hook-up. 2. Connect the positive polarity of the devic

Page 4 - Certification

10 Figure 3 (A and B) - Grounding Possibilities Figure 3 (C and D) - Grounding Possibilities

Page 5 - Compliance Statements

11 4.2 Typical Constant Voltage Operation 1. Before connecting the device to be powered to the power supply, determine the maximum safe load current

Page 6

12 4.3 Setting Current Limit 1. Determine the maximum safe current for the device to be powered. 2. Temporarily short the (+) and (-) terminals of

Page 7 - 2 Introduction

13 4.4 Typical Constant Current Operation 1. Before connecting the device to be powered to the power supply, determine the maximum safe voltage to b

Page 8 - 3 Quick Reference

14 4.5 Constant Voltage/Constant Current Characteristic The working characteristic of this power supply is called a constant voltage/constant current

Page 9 - 3.2 Rear Panel

15 4.6 Saving the Power Supply’s Current State The current state of the power supply is saved after 2 seconds from the last adjustment or after the “

Page 10 - 4 Operating Instructions

16 4.8 Connecting Two Power Supplies in Parallel Two power supplies may be connected in parallel to double the maximum load current. In this configur

Page 11 - 4.1 Instrument Hook-Up

17 If the current equalizing resistors are not well matched, it is preferable that the voltages be slightly unbalanced to achieve current balance. Be

Page 13

18 5.1 RS232 Configuration Overview Baud Rate 9600 bps Parity Bits none Data Bits 8 Start Bits 1 Stop Bits 1 Flow Control Xon / Xoff Terminatio

Page 14 - 4.3 Setting Current Limit

19 3. SAVE<CR> The programmed values of the output current and voltage are saved. If the power supply is restarted, the values of the output cur

Page 15

20 6 Maintenance WARNING The following instructions are for use by qualified personnel only. To avoid electrical shock, do not perform any servicing

Page 16

21 6.3 Calibration Calibration is a procedure that ensures that the power supply will work properly, with parameters specified within the Specificati

Page 17

22 1. Turn on the power supply in calibrating mode a) Turn off the power supply. Disconnect the power cord and all loads connected to the power sup

Page 18

23 2. Zero voltage calibration a) Turn the current coarse knob to select “U 0” for zero voltage calibration and turn the voltage coarse knob. Th

Page 19 - 5 Remote Operation

24 A hexadecimal number between 0 and FFFFh will be shown on the current display. During the zero voltage calibration, the CV LED is lit. b) Connect

Page 20 - 5.2 RS232 Commands

25 A hexadecimal number between 0 and FFFFh is shown on the current display. c) Use the current coarse and fine knobs to adjust the value displayed

Page 21 - 5.3 Application Software

26 A hexadecimal number between 0 and FFFFh is shown on the current display. c) Use the current coarse and fine knobs to adjust the value displayed

Page 22 - 6 Maintenance

27 7 Error Messages The following types of errors may occur: • Self-test errors • Calibration errors • Command errors The first two types of err

Page 23 - 6.3 Calibration

1 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of oper

Page 24 - Figure 11

28 Full voltage calibration errors: Er 30: CC not high Er 31: CV not low Er 32: DAC out of range Er 33: ADC out of range Er 34: ADC system calibration

Page 25

29 8 Specifications 1737 Output Ratings ( 0 °C~40 °C) Voltage 0-60 V Current 0-3 A (0-30 V), 0-2 A (30-60 V) Load Regulation ±(% of output+offset)

Page 26

30 Storage Humidity 85% R.H. Mechanical Specifications Weight 10.5 lbs (4.8 kg) Dimensions (W x H x D) 5.5” x 6.2” x 12.5" (140 x 158 x 318 mm)

Page 27

31 9 Service Information Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain an RMA #. Re

Page 28

32 10 Limited Two-Year Warranty B&K Precision Corp. warrants to the original purchaser that its products and the component parts thereof will

Page 29 - 7 Error Messages

33 (Page intentionally left blank)

Page 30 - 7.3 Command Errors

Printed in Taiwan v063011 22820 Savi Ranch P

Page 31 - 8 Specifications

2 WARNINGS AND CAUTIONS WARNING and CAUTION statements, such as the following examples, denote a hazard and appear throughout this manual. Follow all

Page 32

3 Compliance Statements Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with sepa

Page 33 - 9 Service Information

4 Contents 1 Safety Summary ... 1 2 Introduction ...

Page 34

5 2 Introduction Description The B&K Precision model 1737 is a general purpose dual range DC power source. This power supply can output more vol

Page 35

6 3 Quick Reference 3.1 Front Panel Figure 1 - Front Panel INDICATORS Either the CV or CC LED indicators will be lit whenever the unit is operati

Page 36

7 CURRENT CONTROL 7) Current Coarse Control. Coarse adjustment of current limit. Read value on the red LED display. 8) Current Fine Control. Fine ad

Comments to this Manuals